Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hip Int ; 31(1): 75-82, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31558044

RESUMO

OBJECTIVES: Compare the clinical and radiological outcome of CFP stem with the MiniHip design in a prospective series, with special interest in intraoperative periprosthetic fracture (IPPF). METHODS: We prospectively followed 101 cases treated with the MiniHip stem (Group 1) and 89 with the CFP stem (Group 2) operated between 2010 and 2014. No significant demographic differences were observed between both groups. Median follow-up was 72 months. Average stem length was 41% shorter in the MiniHip group (p < 0.001). Radiological parameters were measured and a logistcic regression model was created to evaluate factors associated with IPPF. RESULTS: Mean mHHS improved from 54 to 95 in the MiniHip group (p < 0.001) and from 64 to 98 in the CFP group (p < 0.001). No significant differences were observed in terms of loosening, infection or instability. We observed 7 IPPFs (3.68%), 3 in group 1 and 4 in group 2. After adjusting for confounders, CFP was not associated with a greater risk of IPPF (OR 3.23; 95% CI, 0.250-42.034, p = 0.368), however, a more complex fracture pattern was observed with this stem design. Prior acetabular fractures were associated with IPPF (OR 66.85; 95% CI, 1.142-3911, p = 0.043). Compared to Dorr A femurs, type Dorr B appeared protective against IPPF (OR 0.039; 95% CI, 0.001-1.109, p = 0.058). Valgus alignment tended to increase the risk of IPPF (OR 20.59; 95% CI 0.870-487.221, p = 0.061). CONCLUSIONS: MiniHip showed similar radiological outcomes to CFP at short- to mid-term follow-up without increasing IPPFs with a shorter stem length. Given that CFP produced a more complex IPPF pattern, surgeons should be cautious with alignment of this particular design, especially in Dorr A femur.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Estudos Prospectivos , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
2.
J Neurol Sci ; 309(1-2): 5-8, 2011 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-21855089

RESUMO

BACKGROUND: Information regarding predisposing factors, frequency, and prognostic implications of new onset atrial fibrillation (NOAF) after carotid endarterectomy (CEA) is scarce. We assessed the frequency, risk factors, and the prognostic impact of NOAF after CEA. METHODS: We assessed every patient undergoing CEA (n = 186) at our academic hospital between 2006 and 2009. Patients underwent continuous electrocardiographic monitoring during surgery and during the rest of hospital stay. We performed univariate and multivariate analyses for identifying variables associated with NOAF and for individualizing variables related to four perioperative adverse outcome measures: a) ischemic stroke; b) ischemic stroke and myocardial infarction, c) ischemic stroke and death, and d) ischemic stroke, myocardial infarction, and death. RESULTS: The study cohort comprised 186 patients. Overall, NOAF was detected in 7 cases (3.8%). The only variable associated with NOAF was intraoperative hypotension (OR 9.6, 95% CI 1.9-47.4, P = .006). There were no perioperative deaths. NOAF was associated with perioperative ischemic stroke and with the combined outcome of ischemic stroke and myocardial infarction. CONCLUSIONS: We found a low frequency of NOAF after CEA. Intraoperative hypotension was associated to a higher risk of NOAF. In turn, NOAF was related to adverse postoperative outcome. Further research is needed to clarify the pathophysiological relation between intraoperative hypotension, NOAF, and adverse CEA outcome.


Assuntos
Fibrilação Atrial/diagnóstico , Endarterectomia das Carótidas/efeitos adversos , Hipotensão/diagnóstico , Complicações Intraoperatórias/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Estudos de Coortes , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Hipotensão/etiologia , Hipotensão/fisiopatologia , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...